Method B: With a Digital Multimeter
Follow steps 1 through 3 of method
OFF)
1.
Confirm that the main switch is off and turn on DIP SW 201-8 on the
main board.
2.
Hook up the multimeter leads as follows:
Positive lead to pin 1 of CN209 on the main board
Negative lead to TP201 (Ground) and select the 20-volt-dc setting.
Note: Hook up the positive lead using a crocodile clip as shown.
3.
Turn on the main switch and enter "99" in the copy counter, then
press the start key.
4.
Adjust VR201 to give a reading of +4 ± 0.2 volts.
Turn off the main switch; then, turn off Dip 201-8 and DIP SW No. 1-1.