Upper slot : Command
Lower slot : Example
AT+CAOC
AT+CAOC
+CAOC : "000024"
OK
AT+CBC
AT+CBC
+CBC : 0,100
OK
AT+CBST=<n>,1,0
AT+CBST=116,1,0
OK
AT+CDIP=<n>
AT+CDIP=0
OK
AT+CEER
AT+CEER
+CEER : 36
OK
AT+CGDCONT
P43
AT+CGEQMIN
P44
AT+CGEQREQ
P44
AT+CGMR
AT+CGMR
1234567890123456
OK
AT+CGREG=<n>
AT+CGREG=0
OK
AT+CGSN
AT+CGSN
123456789012345
OK
AT+CLIP=<n>
AT+CLIP=0
OK
Display last call cost.
Display FOMA terminal's battery level in the "+CBC : <bcs>,<bcl>" format.
bcs=0 : Powered by the battery pack
bcs=2 : Battery pack removed
bcl=0 : No battery remained or battery pack removed
bcl=1-100 : Battery remained
AT+CBC=? : Display a list of displayable values
*1
Set the line to use (Setting of bearer service)
n=116 : 64K data communication (default)
AT+CBST? : Display current settings
AT+CBST=? : Display a list of assignable values
*1
Set whether to notify received sub address. And, subscription status of Multi Number can
be confirmed.
n=0 : The information of sub address is not displayed. (default)
n=1 : The information of sub address is displayed.
AT+CDIP? : Current settings are displayed by "+CDIP:<n>,<m>".
m=0 : Multi Number not subscribed.
AT+CDIP=? : List of the settable values is displayed.
Display reason for disconnection of immediately preceding communication.
Disconnection reason list
*2
Set dialup connection (APN) for packet communication.
*2
Set the criteria for judging whether to permit QoS (Quality of Service) provisioned by the
network when packet communication is established.
*2
Set QoS (Quality of Service) requested to the network at the transmission of packet
communication.
P44
Display FOMA terminal version.
*1
Set whether to report network service registration status. The status reported is Within
service area or Out of service area.
n=0 : Not notified (default)
n=1 : When the terminal is moved from Within service area to Out of service area or vice
versa, the status is reported in the "+CGREG : <stat>" format.
stat=0 : Out of service area
stat=5 : Within service area (during international roaming)
AT+CGREG? : Display the current settings and status in the "+CGREG : <n>, <stat>" format
AT+CGREG=? : Display a list of assignable values
Display FOMA terminal serial No.
*1
Set whether to display sender's caller ID on a PC when receiving 64K data communication.
n=0 : Not display result (default)
AT+CLIP? : Display the current settings and status in the "+CLIP : <n>,<m>" format
m=0 : Network setting not to send caller ID when sending data
m=1 : Network setting to send caller ID when sending data
AT+CLIP=? : Display a list of assignable values
Description
bcs=1 : Not powered by the battery pack
bcs=3 : Power-supply error
n=134 : 64K videophone
m=1 : Multi Number subscribed.
P43
stat=1 : Within service area
n=1 : Display result
40
P43
P44
stat=4 : Unknown
m=2 : Unknown
Need help?