Pump conversions that change a pump from one Stanadyne number to another will need both a new
Stanadyne number and a new Perkins customer part number. These conversions need major pump
component changes or calibration changes and should only be done when a Stanadyne specification suitable
for conversion is available.
When the conversions of this type are made in the Perkins factory the original Stanadyne data plate will remain
in position. A modification data plate (E1), etched with the new Perkins customer part number, the new
Stanadyne model number, and the high idle speed will be fitted.
If an approved Stanadyne service distributor make this type of conversion, they will fit a new Stanadyne data
plate. The new data plate will show a new Stanadyne model number, a new Perkins customer part number
and the original pump serial number and data code. When this occurs, modification data plates fitted by
Perkins should be removed.
Warranty
Pump modifications or conversions done by Perkins and "Range Pumps" which have their high idle reset by
approved Perkins distributors or O.E.M. customers are protected by Stanadyne's warranty in accordance with
the Stanadyne Service Policies and Procedures Manual. Any failures which occur as a direct result of the
Perkins conversion is not protected by the Stanadyne warranty, for example: pump modifications and
conversions.
Electric shut off solenoid (E.S.O.S) changes
Perkins has the option to change the electric shut off solenoid to conform with the voltage or shut off
requirements of an application.
Perkins can change the voltage of operation from 12V to 24V or from 24V to 12V DC or from "Energised - Run"
(ETR) to "Energised - Shut off" (ETOS). A new Perkins customer part number for the pump must be etched on
the modification data plate shown in (E1). An E.S.O.S change will not normally need a new Stanadyne model
number, therefore the new Perkins customer part number will be added to the "Special notes", section of the
Stanadyne pump specification together with the identification of the new solenoid.