Operation 6-11 To Fit - Perkins New 1000 Series Workshop Manual

4 and 6 cylinder diesel engines for industrial and agricultural applications
Hide thumbs Also See for New 1000 Series:
Table of Contents

Advertisement

New 1000 Series
To fit
Special requirements
Description
Bosch fuel injection pump timing pin
Socket Torx drive
The fuel pump gear will only fit in one position. The gear is fitted with the letters C and M at the front.
Caution: Check that the shaft of the fuel injection pump is released, see Operation 11-10 for Bosch pumps
or Operation 11-13 for Lucas/Delphi DP 200 Series pumps.
1 Ensure that the engine is set to TDC with the number one piston on the compression stroke, see Operation
8-1 or Operation 8-2.
2 If the pin (A3) has been removed before the gear is fitted rotate the hub (A1) until the hole (A4) can be seen
in the slot. Fit the small end of the pin (A2) fully into the hole in the pump body. Leave the pin (A3) in position.
3 Fit the fuel pump gear (B1), over the pin (B3) and into mesh with the idler gear (B2).
4 Loosely fit the four fasteners in the centre of the slots (B1) in the gear.
1
2
4
3
5
A
Workshop Manual, TPD 1350E, Issue 4
This document has been printed from SPI². Not for Resale
Special tools
Part number
27610032
27610122
6
A0372/2
Description
Stanadyne and Lucas/Delphi fuel
injection pump timing pin
1
3
B
6
Operation 6-11
Part number
27610033
Continued
2
A0383
139

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents