7.3
PRI System Programming
Description
Selection
PRI Configuration
Assigns the number of B channels which are actually used out of
the 8 PRI line channels (for KX-TD816) or 30 PRI line channels
(for KX-TD1232) and the installation location of the CO line card
(KX-TD181 or KX-TD182) or BRI card (KX-TD281 or KX-
TD282), the CO line unit (KX-TD180), or BRI unit (KX-TD280).
The ISDN layer 1 active mode, ISDN data link mode and ISDN
TEI mode can be also assigned.
KX-TD816
• B channel number and installation spot: 8 Y– – –/0 YY – –
(Y=the card can be installed, – =this area is not changeable)
ex.: 8 Y – – –
Not available.
Status of the expansion area of the system.
Status of the basic area of the system.
the number of available B channels
Programming example:
1. To install TD290 and TD282: 8 Y– – –
KX-TD1232
• B channel number and installation spot: 30 Y–NN/30 N–YN/
(Y=the card can be installed, – =this area is not changeable,
N=the card is not installed.)
ex.: 30
Y – N N
Status of the basic area of the slave system.
Status of the expansion area of the master system.
Status of the basic area of the master system.
the number of available B channels
Programming example:
1. To install TD290 and TD281 to the Master system: 30 Y–NN
2. To install TD290 to the Master and TD280 to the Slave systems:
30 N–NY
• ISDN layer1 mode (L1): Permanent/Call
• ISDN data link mode (L2): Permanent/Call
• ISDN TEI mode (TEI): Fix 0 through 63/Automatic
30 N–NY/26 Y–NY/
26 N–YY/ 22 Y–YN/
18 Y–YY/0 YYYY
Status of the expansion area of the slave system.
450
PRI Section