Cpc Signal Detection Outgoing Set - Panasonic KX-TD816E Installation Manual

Digital super hybrid system.
Hide thumbs Also See for KX-TD816E:
Table of Contents

Advertisement

415

CPC Signal Detection Outgoing Set

Description
Selection
Default
Programming
Conditions
Feature References
4-102
System Programming
4.6
CO Line Programming
Enables or disables CPC Signal Detection during the time between
the originated outside call and the established outside call. If this is
enabled, the system disconnects the line with the time set in
program [405] "CPC Signal Detection Incoming Set" when CPC
Signal is detected.
• CO line number:
KX-TD816 – 01 through 08,
KX-TD1232 – 01 through 24,
• Enable (detection) / Disable (no detection)
Disable
1.
Enter 415.
Display: CPC Outgoing Asn
2.
Press NEXT.
Display: CO Line NO?–>
3.
Enter a CO line number.
To enter CO line number 01, you can also press NEXT.
Display example: CO01:Disable
4.
Keep pressing SELECT until the desired selection is
displayed.
5.
Press STORE.
6.
To program another CO line, press NEXT or PREV, or
SELECT and the desired CO line number.
7.
Repeat steps 4 through 6.
8.
Press END.
• Some central offices (CO) may send CPC-like signals during the
dialling sequence and an attempt to make a call may be terminated. If
your CO is such a type, select "Disable."
• Program [405] "CPC Signal Detection Incoming Set" is used to set
CPC Signal Detection Time.
• In the case of KX-TD1232, CO01 through CO12 are for the Master
System and CO13 through CO24 are for the Slave, if available.
• To assign all CO lines to one selection, press the
this case, the display shows the contents programmed for CO01.
Section 3, Features,
Calling Party Control (CPC) Signal Detection
( =all CO lines)
( =all CO lines)
key at step 3. In