Verilink WANsuite 5260 Reference Manual page 82

Wansuite 5260; wansuite 5230
Table of Contents

Advertisement

Setting
BERT Pattern
Test Duration
Pattern Sync
Elapsed Time
Bit Errors
3-52
W A N s u i t e 5 2 6 0 / 5 2 3 0
Figure 3.41
Serial Interface Test Details Screen
BERT Table on Serial Interface Test Details Screen
The BERT table lets you set the test parameters listed below.
Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.
Values: Net, DTE
Default: Net
Specifies the pattern to be transmitted during a test for the selected port.
Values: Marks, QRSS, 511, 2047, 2
Default: QRSS
15
NOTICE:
The 2
pattern is the ITU (European) version, not the ANSI version.
Specifies the length of time for which the test should run for the selected port.
Values: 15 minutes, 30 minutes, 1 hour, 24 hours, Continuous
Default: 15 minutes
You can also view the following read-only parameters from this screen:
Displays the state of pattern sync during a test. If no test is in progress, "No
Test" is displayed. If a test is active, but the receiver is not in pattern sync,
"No Sync" is displayed. If the receiver is in pattern sync, "In Sync" is
displayed.
Displays the time elapsed since a timed test began or, if completed, the total
test time.
Displays the total number of bit errors detected since the test began or since
error statistics were cleared.
15
, Spaces

Advertisement

Table of Contents
loading

Related Products for Verilink WANsuite 5260

This manual is also suitable for:

Wansuite 5230

Table of Contents