RAS
Reset Timer
3-8
W A N s u i t e 5 2 6 0 / 5 2 3 0
Sets the Remote Alarm Seconds (RAS) threshold. An RAS is generated by
the terminal equipment when an improper signal is received from the facility
(or upon receipt of unframed all ones). The default is 0 seconds (Disabled).
Sets the Reset Timer threshold. This field is the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of "000" means the
alarm will never be reset.
The Network screens provide the user-activated buttons described below.
Button
Function
Submit
Sets any values that have been changed.
Clear Alarms
Resets the alarm conditions and counts to zero.
Performance
Displays a Performance/Summary screen that shows a current
count of the number of error events that have occurred over the
past 24 hours and the past 30 days.
Channels
Displays the Channel Table Details Screen on page 3-21,
showing each channel by index number. Each channel's rate
and service (by number) are displayed and can be changed
through user input.
Network 1 (or
Displays the Services screen for the Network 1 or Network 2
Network 2)
interface.
Services
Refresh
Refreshes data on the current page.
CAUTION:
Performance data will be lost upon power cycle or after performing a
Maintenance Reset/Restart.
Figure 3.5