Verilink WANsuite 5260 Reference Manual page 168

Wansuite 5260; wansuite 5230
Table of Contents

Advertisement

Setting
BERT Pattern
Test Duration
Pattern Sync
Elapsed Time
Bit Errors
Errored Seconds
%EFS
4-52
W A N s u i t e 5 2 6 0 / 5 2 3 0
Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected.
Values: Net, DTE
Default: Net
Specifies the pattern to be transmitted during a test for the selected port.
Values: Marks, QRSS, 511, 2047, 2
Default: QRSS
15
NOTICE:
The 2
pattern is the ITU (European) version, not the ANSI version.
Specifies the length of time for which the test should run for the selected port.
Values: 15 minutes, 30 minutes, 1 hour, 24 hours, Continuous
Default: 15 minutes
You can also view the following read-only parameters from this screen:
Displays the state of pattern sync during a test. If no test is in progress, "No
Test" is displayed. If a test is active, but the receiver is not in pattern sync,
"No Sync" is displayed. If the receiver is in pattern sync, "In Sync" is
displayed.
Displays the time elapsed since a timed test began or, if completed, the total
test time.
Displays the total number of bit errors detected since the test began or since
error statistics were cleared.
Displays the number of asynchronous errored seconds that have been detected
since the test began or since error statistics were last cleared.
Displays the percentage of time that the test ran error-free. This ratio is
derived from the number of error-free seconds divided by the number of
seconds accumulated in Elapsed Time.
Loop Table on Serial Interface Test Details Screen
The Loop table lets you specify the type of Loop test to be performed. The
types of tests available for you to choose from depend on the currently
selected interface.
Values: No Test (Loop Down), Port Loop, V.54 Loop, Far V.54 Loop
Default: No Test (Loop Down)