Verilink WANsuite 5260 Reference Manual page 55

Wansuite 5260; wansuite 5230
Table of Contents

Advertisement

Enforce CIR and Be
Management DLCI
Management Auto IP
DLCI
FrameStart Auto
Diagnostic
FrameStart Auto
Discovery
If this parameter is set to "Yes," the unit will enforce Committed Information
Rate and Excess Burst according to the Link Injection Parameter.
Values: No, Yes
Default: No
NOTICE:
The Auto Diagnostic parameter must be set to "Yes" to enforce CIR and
Be.
If this parameter is set to "0," the unit will look for management traffic on
any DLCI. If set to a number associated with a specific DLCI,
the unit will look for management traffic on that DLCI only.
If this parameter is set to "Yes," the unit will monitor the specified
management DLCI for five pings over 5 seconds, after which the unit uses the
destination address as its management IP address.
When this parameter is set to "Yes," the unit will always source LMI on both
sides of the frame relay connection. The unit will dynamically learn the type
of link management used on each side of the connection (Network and
Serial).
When set to "No," the unit will monitor LMI between the Serial and the
Network port. If one side of the connection goes down, it will source LMI
until the connection goes back up, and will automatically go back to Monitor
mode once both sides are up. In Monitor mode, the unit will switch all frames
received between the network and the serial port regardless of the number of
DLCIs or frame size.
FrameStart Auto Diagnostic mode should be left set to "Yes" unless the frame
relay connection has more that 128 DLCIs, or if there is a very high traffic
rate on a constant basis.
Values: No, Yes
Default: Yes
NOTICE:
If either side of the Frame Relay connection goes down, you will be
unable to remotely access any connected units.
When this parameter is set to "Yes," the unit will send FrameStart discovery
and delay frames to each DLCI it learns as soon as the DLCIs are set active.
This is required to calculate round-trip delay as well as to discover remote
WANsuite 5260/5230/FSE units. This parameter should be set to "Yes" only
on network services that have a WANsuite 5260/5230/FSE at the far end of
the frame relay connection. Also, if set to "Yes," the unit will gather SLA
parameters such as frame and data delivery ratio as defined in the Frame
Relay Forum Implementation, FRF.13. Those gathered statistics are then
displayed on the DLCI Statistics screen as shown on page 3-43.
Values: No, Yes
Default: No
W e b S e r v e r I n t e r f a c e
3-25

Advertisement

Table of Contents
loading

Related Products for Verilink WANsuite 5260

This manual is also suitable for:

Wansuite 5230

Table of Contents