Maintenance Menu; Network Maintenance Menu - Verilink WANsuite 5260 Reference Manual

Wansuite 5260; wansuite 5230
Table of Contents

Advertisement

LOFC
CRCES

Maintenance Menu

Loop
The Loss of Frame Count (LOFC) represents the number of time a loss of
frame is declared. A loss of frame is declared after 2.5 seconds of continuous
loss of signal or OOF.
Sets the Cyclic Redundancy Check Errored Seconds (CRCES) threshold. A
CRC is a method of confirming the integrity of received data.
The MAINTENANCE menu is used to perform loop test functions. From this
menu, Loop tests can be activated and cleared. The WANsuite 5230
Maintenance Menu Tree has the same submenus as the 5260, but does not
have the Network 2 or Serial 2 options.
Figure 5.10
WANsuite 5260 Maintenance Menu Tree
Maintenance
Network 1
Loop
Setting
Pattern
No Test
Net
QRSS
LLB
Service
511
MLB
Idle
2047
Chan 1
2^15
"
Spaces
Ch. 31
Marks
Network 2
(same as "Network 1")
Serial 1
Loop
Setting
Pattern
No Test
Net
QRSS
Port
DTE
511
V.54
2047
Far V.54
2^15
Spaces
Marks
Serial 2
(same as "Serial 1")

Network Maintenance Menu

The following paragraphs describe the user-selectable and display-only
parameters of the 5260's NET 1 and NET 2 and 5230's NET interface
maintenance menu.
Lets you specify the type of loop test (if any) to be performed on the selected
interface.
Values: No Test, Line Loopback (LLB), Maintenance Loopback (MLB)
Default: No Test
Length
Sync
Elapsed
Bit Errs
15 min
(read-
(read-
30 min
only field)
only field)
only field)
1 hr
24 hr
Cont
Length
Sync
Elapsed
Bit Errs
15 min
(read-
(read-
30 min
only field)
only field)
only field)
1 hr
24 hr
Cont
F r o n t P a n e l L C D I n t e r f a c e
ES
% EFS
Cmd
(read-
(read-
(read-
Stop
only field)
only field)
Reset
Err Inject
Start
ES
% EFS
Cmd
(read-
(read-
(read-
Stop
only field)
only field)
Reset
Err Inject
Start
5-9