Trap Log Screen; Top Talkers Screen - Verilink WANsuite 5260 Reference Manual

Wansuite 5260; wansuite 5230
Table of Contents

Advertisement

Trap Log Screen

Top Talkers Screen

Test Details screens provide the following user-selectable prompts:
Prompt
Function
Start BERT
Starts the specified BERT.
Stop BERT
Stops the currently running BERT.
Error Inject
Injects a bit error.
Reset Errors
Resets the current error count.
The Trap Log screen (Figure 4.44) shows a collection of all the traps that
have been generated. A trap is a mechanism that permits a device to send an
alarm for certain network events to an SNMP management station.
The table shown in this screen lists each trap by its Index number, and
displays the type of error captured by the trap (Trap Number) and the date and
time that the trap was stored (Time Stamp).
Figure 4.44
Trap Log Screen
Selecting "Top Talkers" displays the Top Talkers screen (Figure 4.45), which
is used to set parameters for and initiate the generation of a list of IP
addresses ranked in terms of the number of frames and octets they have
transmitted during a specified reporting period. This report allows MIS
managers to determine who is generating the most traffic on a WAN based on
IP addresses.
V T 1 0 0 I n t e r f a c e
4-53

Advertisement

Table of Contents
loading

Related Products for Verilink WANsuite 5260

This manual is also suitable for:

Wansuite 5230