11. SERVICE MODE
11.3.3

MAINTENANCE COUNT.

A. Use
• To enter an appropriate counter value (0 to 999999) as the tentative maintenance time.
• Specify the setting on maintenance counter to "1" or "2": If the maintenance life is
reached, the maintenance call (M1) or service call [Call Service (M1)] will appear.
"0" : Not counted
1
: Counted (The maintenance call display is given when the counter reaches 0.)
2
: Counted (The service call display is given and the initiation of any new copy cycle
is inhibited when the counter reaches 0.)
NOTE
• The counter value is decremented until it reaches -999999 even after it has
counted 0.
B. Procedure
• The default setting is 0.
• When "1" or "2" is selected, a screen will then appear to allow the counter value to be
entered.
11.3.4

IU LIFE STOP MODE

A. Use
• When the supplies life count. reaches the life value, the IU life will be detected.
• The mode when the IU life is reached, is specified by this setting.
CONTINUOUS : Enables copying. Maintenance call (M2) display is given.
STOP
: Disables copying. Service call [Call Service (M2)] display is given and
NOTE
• When the drum reaches its life value, the image quality of subsequent prints is out
of warranty.
B. Procedure
• The default setting is STOP.
11.3.5

ID ADJUST

A. Use
• To set the image density by varying Vg and Vb on the engine side.
• Used when the image density is high or low.
B. Procedure
• The default setting is 0.
86
the initiation of any new copy cycle is inhibited.
CONTINUOUS/"STOP"
-3 to +3 (1step: 20 V)
Field Service Ver. 2.0 Jun. 2010