14-7
7. Remove the cylinder from the machine for service
or inspection. (fig. 14-7)
Note: At this time the pivot bushings and pivot pins are
easily accessible for replacement. Inspect them for vis-
ible wear or damage and replace them as necessary .
Installation
1. To install the lift arm cylinder, reverse the removal
procedure.

Bucket/Tilt Cylinder

Removal
Required Tools
Socket Wrench
Combination/Open End Wrench
Hammer
Punch (brass)
14-8
1. Raise the lift arms and support them with the lift
arm brace as described on page 4-1. (fig. 14-8)
14-9
2. Place a suitable catch container beneath the cylin-
der fittings, then disconnect the inlet and outlet
hoses from the cylinders. (fig. 14-9)
3. Cap and plug the hoses and fittings to prevent fluid
loss and or system contamination.