Terex PT-100G Forestry Service Manual page 126

Compact track loader
Hide thumbs Also See for PT-100G Forestry:
Table of Contents

Advertisement

Compact Track Loader
18. Troubleshooting
Quick Attach
Quick Attach
Display reads:
Fault results in:
Invalid Keypad Installed
Quick attach output de-energized
Loss of communications
Quick attach output de-energized
between Main Controller
and Keypad
Quick Attach Solenoid
Quick attach output de-energized
fault
Work Enable solenoid
Quick attach output de-energized
fault
Work Enable solenoid
Quick attach output de-energized
fault
Work Enable solenoid
Quick attach output de-energized
fault
Electric Auxiliary
Electric Auxiliary
Display reads:
Fault results in:
Loss of communications
Electrical auxiliary disabled
between Main Controller
and Left Joystick
Possible causes:
CE keypad installed in US machine or vice versa. Install correct keypad for your machine, then cycle
Faulty connections or wires between keypad and
main controller
Solenoid shorted to battery/ground
or open circuit (faulty wires, connections)
Solenoid shorted to battery (faulty wires,
connections)
Solenoid shorted to ground (faulty wires,
connections)
Solenoid open circuit (faulty wires, connections)
Possible causes:
Faulty connections or wires between left joystick
and main controller
* Output fault detection does not work for load
connected to outputs
18-10
Solution:
power
Restore communications, then cycle power by
turning the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Solution:
Restore communications, then cycle power by
turning the key off then back on