Terex PT-100G Forestry Service Manual page 125

Compact track loader
Hide thumbs Also See for PT-100G Forestry:
Table of Contents

Advertisement

Low Flow Auxiliary
Low Flow Auxiliary
Display reads:
Fault results in:
Low Flow Rocker voltage
Low flow variable disabled
above upper limit
Low Flow Rocker voltage
below lower limit
Invalid Keypad installed
Low flow disabled
Lap Bar Switch
Low flow control disabled
Fault (both inputs off)
Lap Bar Switch
Low flow control disabled
Fault (both inputs on)
Keypad CAN Fault -
Low flow control disabled
Loss of Keypad
CAN communications
OX CAN Fault -
Low flow control disabled
Loss of Output Module
CAN Communications
Engine CAN Fault -
Load sharing disabled
Loss of Engine
CAN communications
Low Flow Rocker
Low flow variable disabled
not calibrated
Low Flow Male
Low flow male disabled
not calibrated
Low Flow Female
Low flow female disabled
not calibrated
Low Flow Male solenoid
Low flow disabled, work enable solenoid de-
short circuit
energized
Low Flow Male solenoid
Low flow disabled, work enable solenoid de-
short circuit
energized
Low Flow Male solenoid
Low flow male disabled
open circuit
Low Flow Female solenoid
Low flow disabled, work enable solenoid de-
short circuit
energized
Low Flow Female Solenoid
Low flow disabled, work enable solenoid de-
short circuit
energized
Low Flow Female solenoid
Low flow female disabled
open circuit
Work Enable solenoid
Low flow disabled
fault
Work Enable solenoid
Low flow disabled
fault
Work Enable solenoid
Low flow disabled
fault
Possible causes:
Faulty joystick
Faulty joystick
CE keypad installed in US machine or vice versa. Install correct keypad for your machine.
Switch faulty, wiring connection faulty, switch out
of adjustment.
Switch faulty, wiring connection faulty, switch out
of adjustment.
Faulty connections or wires between keypad and
main controller
Faulty connections or wires between main
controller and output module
Faulty connections or wires between engine and
Main controller
Parameter setting out of valid range
Parameter setting out of valid range
Parameter setting out of valid range
Solenoid shorted to battery (faulty wires,
connections)
Solenoid shorted to ground (faulty wires,
connections)
Solenoid open circuit (faulty wires, connections)
Solenoid shorted to battery (faulty wires,
connections)
Solenoid shorted to ground (faulty wires,
connections)
Solenoid open circuit (faulty wires, connections)
Solenoid shorted to battery (faulty wires,
connections)
Solenoid shorted to ground (faulty wires,
connections)
Solenoid open circuit (faulty wires, connections)
18-9
Compact Track Loader
18. Troubleshooting
Solution:
Replace joystick, then cycle power by turning the
key off then back on
Replace joystick, then cycle power by turning the
key off then back on
Restore connections, adjust or replace switches,
then cycle power by turning the key off then back
on
Restore connections, adjust or replace switches,
then cycle power by turning the key off then back
on
Restore communications, then cycle power by
turning the key off then back on
Restore communications, then cycle power by
turning the key off then back on
Restore communications, then cycle power by
turning the key off then back on
Perform low flow rocker calibration proecedure
Perform low flow male end current calibration
procedure
Perform low flow female end current calibration
procedure
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on
Restore connections, then cycle power by turning
the key off then back on