Propel (continued)
Right Forward Threshold
Propel automatically limited to default threshold
not calibrated
parameters
If threshold < 4000, limit to 4000, If > 6000, limit
to 6000
Right Reverse Threshold
Propel automatically limited to default threshold
not calibrated
parameters
If threshold < 4000, limit to 4000, If > 6000, limit
to 6000
Left Forward high speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Left Forward low speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Left Reverse high speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Left Reverse low speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Right Forward high speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Right Forward low speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Right Reverse high speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Right Reverse low speed
Propel automatically limited to default parameter
End Current
setting
not calibrated
(If parameter is out of range, limits to max current,
15030)
Brake Solenoid
Propel disabled (ramp to stop)
short circuit
Brake Solenoid
Propel disabled (ramp to stop)
short circuit (to power)
Brake Solenoid
Propel disabled (ramp to stop)
open circuit (to ground)
Drive Enable Solenoid
Propel disabled
short circuit (to power)
Drive Enable Solenoid
Propel disabled
short circuit (to ground
Drive Enable Solenoid
Propel disabled
open circuit
2-Speed Solenoid
High range propel disabled
fault
Left Fwd Solenoid
Propel disabled
short circuit
(de-energizes drive enable solenoid)
Left Fwd Solenoid
Propel disabled
short circuit
(de-energizes drive enable solenoid)
Left Fwd Solenoid
Machine stops immediately and returns to neutral.
open circuit
Forward propel is disabled and reverse propel is
limited to parameter setting (Default 50%)
Left Rvs Solenoid
Propel disabled
short circuit
(de-energizes drive enable solenoid)
Left Rvs Solenoid
Propel disabled
short circuit
(de-energizes drive enable solenoid)
Left Rvs Solenoid
Machine stops immediately and returns to neutral.
open circuit
Reverse is disabled and forward propel is limited
to parameter setting (Default 50%)
Right Fwd Solenoid
Propel disabled
short circuit
(de-energizes drive enable solenoid)
Right Fwd Solenoid
Propel disabled
short circuit
(de-energizes drive enable solenoid)
Threshold needs to be calibrated
Threshold needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
End current needs to be calibrated
Faulty connections or wires to or from brake
solenoid, faulty solenoid.
Faulty connections or wires to or from brake
solenoid, faulty solenoid.
Faulty connections or wires to or from brake
solenoid, faulty solenoid.
Faulty connections or wires to or from drive
enable solenoid, faulty solenoid.
Faulty connections or wires to or from drive
enable solenoid, faulty solenoid.
Faulty connections or wires to or from drive
enable solenoid, faulty solenoid.
Faulty connections or wires to or from 2-speed
solenoid, faulty solenoid.
Faulty connections or wires to or from left fwd
solenoid, faulty solenoid.
Faulty connections or wires to or from left fwd
solenoid, faulty solenoid.
Faulty connections or wires to or from left fwd
solenoid, faulty solenoid.
Faulty connections or wires to or from left reverse
solenoid, faulty solenoid.
Faulty connections or wires to or from left reverse
solenoid, faulty solenoid.
Faulty connections or wires to or from left reverse
solenoid, faulty solenoid.
Faulty connections or wires to or from right fwd
solenoid, faulty solenoid.
Faulty connections or wires to or from right fwd
solenoid, faulty solenoid.
18-5
Compact Track Loader
18. Troubleshooting
Perform threshold calibration procedure
Perform threshold calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Perform end current calibration procedure
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on