Springs
9-7
11. Disconnect the exhaust springs (6) on either side
of the middle exhaust pipe. Remove the lower and
middle exhaust pipes to gain access to the cooler
filler tube (fig. 9-7).
9-8
12. Remove the heat guard which protects the charge
intake and cooler return hoses in the rear left side
of the tank (fig. 9-8).
Cooler Filler tube
from check valve
9-9
13. Disconnect the filter tube from the cooler inlet tube
and check valve connected to the hydraulic filter.
Then remove cooler inlet tube from the check
valve adapter (fig. 9-9). Both tubes can then be
removed from the machine.
Cooler Filler
tube
Cooler Filter Tube
from hydraulic filter
9-3
9-10
14. Remove both the auxiliary inlet and return
hoses from the right front of the hydraulic tank
(fig. 9-10).
Hose
9-11
15. Remove the auxiliary case drain hose from the
tank (fig. 9-11).
9-12
16. Disconnect the cooler return and intake hoses
from the tank (fig. 9-12).
Compact Track Loader
9. Hydraulic Reservoir
Hoses