Installation Procedure; Footwell - Terex PT-100G Forestry Service Manual

Compact track loader
Hide thumbs Also See for PT-100G Forestry:
Table of Contents

Advertisement

Main fuel
gas line
location
7-7
7-8
7. Remove the allen head plug from the cleanout
plate located on the rear, bottom side of the fuel
tank. Allow fuel to drain into a suitable catch
container (fig. 7-8).
Note: Collect and contain flammable liquids in suitable
containers. Dispose of all liquids in accordance with
local regulations and mandates.
7-9
8. Remove the bolts securing the fuel tank to the
rear mounting plate and fenders (fig. 7-9).
Bolts
out
up
7-10
9. Lift and remove the tank from the machine
(fig. 7-10).
Installation
1. To install the fuel tank, reverse the removal
procedure.

Footwell

Removal
Required Tools
Screwdriver
Combination/Socket Wrench
1. Raise and support the lift arms as described on
page 4-1 of this manual. (optional)
2. Tilt and support the operator enclosure (cab) as
described on page 4-2 of this manual.
7-11
3. Remove the bolts that secure the floor mat to the
footwell and remove the mat from the machine
(fig. 7-11).