BOMBARDIER 1980 Shop Manual page 202

Hide thumbs Also See for 1980:
Table of Contents

Advertisement

SECTION 04
SUB-SECTION 02, (ELECTRICAL TESTS)
TWO CYLINDER ELECTRONIC IGNITION ENGINE
6.
GENERATOR COIL OUTPUT
1. Disconnect wire connectors from C.D.!. electronic
boxes.
2. Using one (1) harness adaptor. connect tester P test
lead to red wire of one of the two connectors removed
from C.D.I. electronic boxes. Connect N test lead to
ground; do not use brown wire as ground.
3.
Set tester sWitch and dial as follows:
Engine type
Switch position
Dial
354. 454
HIGH
40
4 . Turn ignition key to ON position. disable cut-out button
circuit and tether cut-out switch then crank engine.
+
WARNING: To prevent powerful electric shocks
with engine running, do not touch any component
related to electronic ignition system (ignition coil, high
tension wire, wire harness, etc ... )
A. Indicator lamp lights: Coil output is up to specifi-
cations. Repeat test at least three (3) times to venfy
reading and consistency.
B. Indicator lamp does not light: If trigger coil (no. 7)
is positive. the problem IS a faulty generator coil.
+
WARNING: Do not touch tester P lead clip while
cranking the engine. Also make sure that tester
P lead clip does not contact any metallic object.
7. TRIGGER COIL OUTPUT
1. Disconnect electronic box connectors.
Magneto side:
Connect tester P lead to white wire.
P.T.O. side:
Connect tester P lead to white/red
wire.
Connect tester N lead to a good engine ground.
2. Set tester sWitch and dial as follows:
Connector of one
of the two
~
electroniC boxes ~-y~
Engine type
Switch position
Dial
354. 454
LOW
50
3. Turn Ignition key to ON position. disable cut-out button
circuit then crank engine.
+
WARNING: To prevent powerful electric shocks
with engine running, do not touch any component
related to electronic ignition system (ignition coil, high
tension wire, wire harness, etc ... )
A. Indicator lamp lights: Trigger coil output IS up to
specifications. Repeat test at least three (3) times to
verify reading and check for consistency.
B. Indicator lamp does not light: The problem IS a faulty
trigger coil.
O
NOTE: If no output IS Indicated on trigger coil.
carefully inspect the trigger ground connection wire
connected to C.D.I. electronic box retaining screw. Clean
and tighten connection then repeat test.
(BOMBARDIER IGNITION TESTER). PAGE 7