Air Cleaner Element Inspection and Cleaning

Inspect and clean element
Every 1 000 km (600 miles, 3 months)
Inspection
1) Remove the air cleaner element. Refer to "Air
Cleaner Element Removal and Installation in Section
1D (Page 1D-5)".
2) Inspect the air cleaner element for clogging. If it is
clogged with dirt, clean or replace it with a new one.
CAUTION
!
If driving under dusty conditions, inspect or
clean the air cleaner element more frequently.
The surest way to accelerate engine wear is
to operate the engine without the element or
to use a torn element. Make sure that the air
cleaner is in good condition at all times. Life
of the engine depends largely on this
component.
3) After finishing the air cleaner element inspection,
reinstall the removed parts.
Cleaning
1) Remove the air cleaner element assembly. Refer to
"Air Cleaner Element Removal and Installation in
Section 1D (Page 1D-5)".
2) Separate the polyurethane from element.

Repair Instructions

3) Carefully use compressed air to clean the air cleaner
B931G20206001
element.
CAUTION
!
Always apply compressed air to the inside of
the air cleaner element. If compressed air is
applied to the outside, dirt will be forced into
the pores of the air cleaner element,
restricting air flow through the air cleaner
element.
4) After cleaning the air cleaner element, reinstall the
removed parts.
5) Drain water from the air cleaner by removing the
drain plug.
6) Reinstall the drain plug.
I831G1020002-01
Maintenance and Lubrication:
0B-3
I831G1020003-01
I831G1020004-01