Example
For error frame seconds event, configure the error threshold as 8 and the event
detection interval as 30 seconds on Fast Ethernet port 5:
TL-SL5428E(config)# interface fastEthernet 1/0/5
TL-SL5428E(config-if)#
threshold 8 window 300
ethernet-oam remote-failure
Description
The ethernet-oam remote-failure command is used to configure whether to
notify the link faults or not. The link faults include dying gasp and critical event.
To return to the default configurations, please use no ethernet-oam
remote-failure command.
Syntax
ethernet-oam remote-failure { dying-gasp | critical-event } notify { disable |
enable }
no ethernet-oam remote-failure { dying-gasp | critical-event } notify
Parameter
dying-gasp —— Dying Gasp link event. Dying gasp means an unrecoverable
fault, such as power failure, occurs.
critical-event —— Critical Event. Critical-event means unspecified critical event
occurs.
notify ——Enable/Disable the event notification. By default, it is enabled.
Command Mode
Interface Configuration Mode (interface fastEthernet / interface range
fastEthernet / interface gigabitEthernet / interface range gigabitEthernet)
Example
Disable the Dying Gasp link event notification on Fast Ethernet port 7:
TL-SL5428E(config)# interface fastEthernet 1/0/7
TL-SL5428E
JetStream L2 Managed Switch CLI Guide
ethernet-oam
222
link-monitor
frame-seconds