Setup Menu: Alarm/Warning - Cisco D9854 Installation And Operation Manual

Advanced program receiver
Table of Contents

Advertisement

Setup Menu: Alarm/Warning

Structure
To view the Alarm/Warning menu from the Main menu, press the RIGHT arrow
key once and then the SELECT key to reach the Setup menu. Then press the RIGHT
arrow key six times and the SELECT key to view the Alarm/Warning menu.
The Alarm/Warning menu allows to you to browse the active alarms and
warnings, and set whether the output will be disabled in the event of an alarm. This
menu has the following structure:
Alarm/Warning
FP Alarm Reminder
Disable
System Alarm Name
Loss Of Signal
System Warning Name
PMT Timeout
ALARM/WARNING
FP Alarm Reminder
Description:
Parameters:
Alarm Vid Cutoff
Description:
Parameters:
4-88
Model D9854 Advanced Program Receiver Installation and Operation Guide
Alarm Vid Cutoff
Disable
Enb Rly Trp
Yes Yes Yes
Enb Rly Trp
Yes Yes Yes
When this function is enabled, the highest priority alarm flashes on
the LCD display for a two-second interval every 10 seconds. The
alarm will continue to flash periodically until it is either cleared or
the function is disabled.
Enable or Disable.
Sets whether the video output is cut off if any enabled alarm is
active on the receiver. When video is cut off, there will be no
horizontal or vertical synchronization on the output. This is useful
for downstream redundancy switching by detecting a loss of video
signal.
Note: This function also exists under Setup: Services: Video.
Enable or Disable. The default is Disable.