Alarm
Message
Type
Flash STORAGE
Set
Clear
LNB PS
Set
Clear
Signal Quality
Set
Clear
6-10
Message
RECORD: init failed
RECORD
MANAGER: Record
contents check error,
erasing all
RECORD: sector
setup check error,
erasing sector
RECORD: init done
LNBPS: No Load
LNBPS: Over
Temperature
LNBPS: Over Loaded
LNBPS: Short Circuit
LNBPS: Normal
LNBPS: Disabled
LNBPS: Off
Audio Muted due to
RF noise
Unstable RF Signal
Poor Quality RF
Signal
Signal Quality Fault
Cleared
Audio Unmuted
Model D9854 Advanced Program Receiver Installation and Operation Guide
Cause/Remedy
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
Cause: RF Signal
quality is poor due to
interference or signal
level issues.
Remedy: Check RF
settings, re-aim dish,
and add signal
amplifier.
Description
Severity
Non-volatile
Major
storage system
corrupted.
Possible loss of
configuration.
NVS Corruption,
and loss of
configuration
data
NVS Corruption,
and loss of sector
data
LNB power
Minor
overload
LNB power OK
Signal is locked
Minor
but BER is
beyond Audio
muting
threshold.
Signal lock
status is toggling
frequently.
Signal is locked
but BER is
beyond muting
threshold.