Cisco D9854 Installation And Operation Manual page 259

Advanced program receiver
Table of Contents

Advertisement

Alarm
Message
Type
Transport
Set
Processing
Clear
Temperature
Set
Alarm
Clear
Fan
Set
Clear
FPGA
Set
Temperature
Alarm
Clear
4021470 Rev D
Message
PTI lockup
PTI running
Temperature over
Alarm threshold
Temperature normal
Fan Failure Alarm
Fan RPM Alarm
Clear Fans Alarm
Temperature over
Alarm threshold
Temperature normal
D9854 Advanced Program Receiver Installation and Operation Guide
Cause/Remedy
Cause: Possible
software issue
Remedy: Clear
alarms, reset unit,
and notify customer
service if problem
persists
Cause: Room
temperature too high,
or air flow is blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature or
improve air flow to
device.
Cause: Hardware
issue.
Remedy: Unit should
be returned to
customer service as
soon as possible.
Cause: Room
temperature too high,
or air flow is blocked.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature or
improve air flow to
device.
Description
Severity
Programmable
Minor
transport input
module stopped
processing any
data packet.
Temperature is
Major
above safe
operating range.
Fan failure
Major
Fan RPM out of
normal
operating range.
FPGA
Major
temperature is
above safe
operating range.
6-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents