Cisco D9854 Installation And Operation Manual page 268

Advanced program receiver
Table of Contents

Advertisement

Warning
DRT timeout #
MCT Timeout #
ECT Timeout #
Memory Usage Host Set
6-20
Message
Message
Type
Set
drt # timed out
drt # is lost
Clear
drt fault cleared
Set
mct # timed out
mct # is lost
Clear
mct fault cleared
Set
ect # timed out
ect # is lost
Clear
ect fault cleared
Excessive (stack/
partition) memory
usage
Clear
Normal (stack/
partition) memory
usage
Model D9854 Advanced Program Receiver Installation and Operation Guide
Cause/Remedy
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Cause: Possible software
issue.
Remedy: Clear warnings,
reset the unit, and notify
customer service if the
problem persists.
Description
Disaster Recovery
Table was never
received.
No longer receiving
Disaster Recovery
Table.
Inband Control Table
was never received.
No longer receiving
Inband Control
Table.
Event Control Table
was never received.
No longer receiving
Event Control Table.
SW exceeding
allowable memory
usage.
4021470 Rev D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents