Table of Contents

Advertisement

Alarm
Message
Type
PE n: Loss of
Set
Input
Clear
Digital Program
Set
Mapping
Clear
Shutdown Event Set
6-6
Message
Loss of input
detected
Fault reset
PID Collision
Program Collision
Mode-i PMT out of
range
Digital Program
Mapping - OK
DL APP REBOOT
I2C Failure
User requested FPGA
change
User requested APP
change
Model D9854 Advanced Program Receiver Installation and Operation Guide
Cause/Remedy
Cause: Loss of input.
Remedy: Ensure
input has a valid
stream.
Cause: Uplink
settings may have
changed since setting
up the unit. Please
check your DPM
settings.
Remedy: Correct the
DPM settings. Check
the uplink to find the
appropriate system
settings.
Cause: User request
requires reboot or
internal system error.
Remedy: If it is an
internal system error
fault, clear alarms,
reset the unit, notify
customer service if
the problem persists.
Description
Severity
Loss of input.
Minor
Two source
Minor
service PIDs are
being mapped to
the same output
PID. This will
cause data
corruption in the
stream.
Two source
channel numbers
are being
mapped/passed
to the same
channel number
in the output.
PMT PID to be
used for Mode-i
is outside of
valid MPEG PID
range.
New application
Major
downloaded,
system requires
reboot.
Internal system
error.
Runnable FPGA
change requires
reboot.
Runnable
application
change requires
reboot.