Cisco D9854 Installation And Operation Manual page 261

Advanced program receiver
Table of Contents

Advertisement

Alarm
Message
Type
BOOT HOST
Set
Clear
Boot Secondary
Set
4021470 Rev D
Message
KB not accessible
LCD not connected
FLASH Not Found
EMI SDRAM Test
Failed
BOOT Invalid
FPGA Invalid
APP Invalid
BOOT passed
FLASH Not Found
EMI SDRAM Test
Failed
BOOT Invalid
FPGA Invalid
D9854 Advanced Program Receiver Installation and Operation Guide
Cause/Remedy
Cause: Hardware
issue
Remedy: Clear
alarms, reset unit,
and notify customer
service if the problem
persists.
Cause: Hardware
issue.
Remedy: Clear
alarms, reset the unit,
and notify customer
service if the problem
persists.
Description
Severity
KB is not
Major
detected by Boot
code.
LCD is not
detected by Boot
code.
Flash memory
not detected.
RAM Failure -
memory testing
failed.
Boot SW cannot
be read from
memory
correctly.
FPGA Image
cannot be read
from memory
correctly.
Application SW
cannot be read
from memory
correctly.
Flash memory
Major
not detected.
RAM Failure -
memory testing
failed.
Boot SW cannot
be read from
memory
correctly.
FPGA Image
cannot be read
from memory
correctly.
6-13