Cisco D9854 Installation And Operation Manual page 267

Advanced program receiver
Table of Contents

Advertisement

Warning
PMT timeout #
PAT timeout #
NIT timeout #
CAT timeout #
4021470 Rev D
Message
Message
Type
Set
pmt # timed out
pmt # is lost
Clear
pmt fault cleared
Set
pat # timed out
pat # is lost
Clear
pat fault cleared
Set
nit timed out
nit is lost
Clear
nit fault cleared
Set
cat timed out
cat is lost
Clear
cat fault cleared
D9854 Advanced Program Receiver Installation and Operation Guide
Cause/Remedy
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
the problem persists,
determine if uplink is
sending the current SI
information table. Disable
the warning if not using the
table.
Description
Program Mapping
Table was never
received.
No longer receiving
Program Mapping
Table.
Program Association
Table was never
received.
No longer receiving
Program Association
Table.
Network Information
Table was never
received.
No longer receiving
Network Information
Table.
Conditional Access
Table was never
received.
No longer receiving
Conditional Access
Table.
6-19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents