Cisco D9854 Installation And Operation Manual page 146

Advanced program receiver
Table of Contents

Advertisement

Setup Menu: Outputs: TS Out: DPM,
Synchronizing Output Services
To synchronize the output to the input Services Only:
This operation synchronizes the inputs to the outputs according to the service
assignments only. This is useful when you already have PID assignments set for the
services but want to ensure that the services are mapped correctly.
1. On the DPM menu, map the output services as desired.
2. Select PE Resync: Svcs. The receiver will synchronize the PE output according to
the available input services only, and ignore the input to output service PID
mapping.
To synchronize the output to the input PIDs only:
This operation synchronizes the inputs to the outputs according to the PID
assignments only. This is useful when you have already have the services set up but
want to synchronize to the incoming PIDs.
1. On the DPM menu, map the output services as desired.
2. Select PE Resync: PIDs. The receiver will synchronize the PE output according
to the input PIDs only, and ignore the service assignment categories/names.
To synchronize the output to All (Services and PIDs):
This operation synchronizes the inputs to the outputs of the current PMT according
to the service assignments and then the PID assignments. This is similar to a sample
and hold function.
1. On the Detailed Program Mapping Active menu, map the outputs services as
desired.
2. Select PE Resync: All. The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
To synchronize the output to a Template:
Using a template allows you to preset the input to output mapping of a PE
according to the preset template. This is helpful in preconfiguring any number of
PEs for future use.
4-84
Model D9854 Advanced Program Receiver Installation and Operation Guide
Continued
4021470 Rev D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents