Black Box 5000 series Reference Manual page 80

5000 series bridge/router ppp menu reference manual
Hide thumbs Also See for 5000 series:
Table of Contents

Advertisement

Menus Reference Manual: Edit Remote Site Menu – Connection Set-Up Menu
F – Multiple link connection, primary link set to Frame Relay, secondary to ISDN.
Option
1. ISDN call set-up
2. Primary link
3. DLCI
4. CIR
5. EIR
6. Time interval
7. PPP
8. State
Enter option number, "=" - main menu, <TAB> - previous menu
>
The REMOTE SITE CIRCUIT SET-UP MENU allows the setting of frame relay parameters used to configure the
Permanent Virtual Circuit (PVC) that is used to connect to this remote site. Up to 128 remote site PVCs may be defined.
1 - ISDN Call Set-Up
The ISDN Call Set-up option takes you to the ISDN Call Set-Up Menu for the chosen remote site. Here you set
parameters such as the ISDN numbers of the remote partner ISDN routers and redial timers that pertain to ISDN circuit
activation.
2 - Primary Link
The Primary link option defines the primary link number that will be used to connect to this remote site.
Options: 1, 2, none
Default:
[none]
Considerations:
The PVC must be toggled (disable – enable option 8. State) before this option may be takes effect.
REMOTE SITE n CONNECTION SET-UP MENU
Value
menu
- Configure ISDN calls
[7]
- Configure primary link number
[16]
- Frame relay address
[0 Kbps]
- Committed information rate
[link_speed]
- Excess information rate
[10 (1/10th s)]
- Interval for monitoring bandwidth
[disabled]
- Enable/disable PPP over Frame Relay
[disabled]
- Enable/disable PVC
80
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lr5100a-tLr5200a-r2

Table of Contents