Default: [Network] - Black Box 5000 series Reference Manual

5000 series bridge/router ppp menu reference manual
Hide thumbs Also See for 5000 series:
Table of Contents

Advertisement

5/6 – Slot/Channel Set-Up
This option taskes you to the Slot/Channel Set-Up menu, where the number of channels / time slots to be used and their
operating parameters may be selected.
6/7 – Line Encoding
The Line Encoding option sets the line-coding format used. Line encoding requirements will be specified by your service
provider.
Choices:
if T1: AMI, INV_AMI, B8ZS
if E1: AMI, INV_AMI, HDB3
Default:
if T1: [B8ZS]
if E1: [HDB3]
7/8 – Clocking
The Clocking option selects the source for the data transmission timing and sychronization clock (received data is clocked
from the received signal).
Network timing loops the received data clocking back to the network for transmission clocking. This setting will normally
be used over links from a service provider.
Internal clocking uses the oscillator on the T1/E1 interface of this router to provide the clock signal for transmitted data.
This setting could be used on a private line end to end link, with one end providing the clocking (the other end would be
set to network clocking).
Choices:
network, internal
Default:
[network]
8/9 – Alarm Generation
This option toggles this routers ability to generate yellow Carrier Failure alarm notifications after detecting received signal
errors.
9 – T1.403 PRM
This option toggles ANSI specification T1.403 CSU performance reporting between enabled and disabled. If enabled,
peformance data is transmitted once per second.
Menus Reference Manual: T1/E1 Set-Up Menu