5.5.18 SOFTLOADSTATUSB
This log returns current status of the software upgrade process. It is used only when upgrading the G-III
Reference Receiver firmware.
Output states:
Valid trigger:
Frequency:
Message ID:
Header Format:
Field
Field
Name
1
Header
G-III log header
Current status of the upgrade process.
2
Status
See Table 49, SOFTLOADSTATUSB Status Values on Page 124
3
32-bit CRC
Value
1
NOT_STARTED
3
READY_FOR_DATA
4
DATA_VERIFIED
5
WRITING_FLASH
6
WROTE_FLASH
8
COMPLETE
9
VERIFYING_DATA
10
ERASING_FLASH
12
MULTIPLE_IMAGES_IN_FLASH
Note: Any status >= 16 is an error code
19
BAD_PLATFORM
20
BAD_MODULE
29
BAD_IMAGE_CRC
30
IMAGE_OVERSIZE
32
BAD_FLASH_ERASE
33
BAD_FLASH_WRITE
124
Configuration, Operational, Maintenance
ONCE, ONNEW, ONTIME
Once per second
4110
G-III Log
Description
Table 49: SOFTLOADSTATUSB Status Values
Name
Description
Process has not begun.
Ready to receive data.
Data saved to flash has passed CRC.
Storing data to flash.
Data stored in flash.
Upgrade complete.
Verifying the data stored in flash.
Erasing the flash.
Multiple application images have been found in flash.
This data cannot be loaded onto this platform.
The data cannot be loaded into the APP NVM block.
CRC of the received image has failed.
The received image is too large to store in flash.
Erasing of flash failed.
Writing of flash failed.
WAAS G-III Reference Receiver User Manual Rev 1
Data Logs
Binary
Format # Bytes
Offset
H
0
Ulong
4
H
Hex
4