4.4.17 PULSEBLANKING

The PULSEBLANKING command can fundamentally change the way that the receiver operates.
Do not alter the default settings unless you are confident that you understand the consequences.
This command enables or disables digital pulse blanking. The sensitivity of the digital pulse blanking may be
adjusted using the threshold field. When the pulse blanking extension time is non-zero, the receiver will
continue to blank the signal for the specified extension time.
Valid States:
Valid Modes:
Acceptable Ports:
Syntax:
PULSEBLANKING frequency threshold exttime
Example:
PULSEBLANKING L2 0 2
PULSEBLANKING L5 120 4
Field
Field Name
1
frequency
2
threshold
3
exttime
WAAS G-III Reference Receiver User Manual Rev 1
Configuration, Operational
Normal
Data
Specifies which frequency type to apply the
command to.
Pulse Blanking threshold
To turn off pulseblanking, set the threshold value to 0.
Pulse blanking extension time (μs)
Description
Chapter 4
Range
Precision
L1
L2
N/A
L5
0-127
Int
0-10
Int