Firmware Updates
6.4

Update the G-III Reference Receiver Firmware

There are two ways to perform a software update on the G-III Reference Receiver, either through Ethernet
using the softload protocol or through COM port serial loading using WinLoad. It is not necessary to do both.
6.4.1

Serial Port Loading using WinLoad

Follow these steps to load the G-III Reference Receiver using a computer and NovAtel's COTS program
Winload.
1. Connect the MAINTENANCE port on the G-III Reference Receiver to a COM port on the
computer using an RS-232 serial cable.
2. Open WinLoad.
3. Click File | File Open and browse to the executable object code .hex file. This selects the file that
will be loaded.
4. Click Settings | Com Settings to choose the com port settings. Select the appropriate COM port,
select the highest supported baud rate for the download baud rate (typically 115200 bps via a
computer port, but could be higher if using a device such as an EdgePort) and select 9600 for the
connect baud rate. Click OK.
5. Disconnect power from the G-III Reference Receiver.
6. Click Write Flash to start the loading process.
7. Restore power to the G-III Reference Receiver. WinLoad searches for a specified period for the
receiver. If the receiver is not found, confirm the COM settings are correct and the receiver is
connected, then start again.
8. The loading process begins. If prompted for an auth code, click Skip.
9. When the loading process completes, the receiver should automatically reboot.
6.4.2

Ethernet Softload Protocol

Use the following procedure to update the firmware using the softload protocol:
1. Connect the DATA port on the G-III Reference Receiver to an Ethernet port on the computer using
an Ethernet cable.
2. Transition the G-III Reference Receiver to the Maintenance state.
CHANGESTATE MAINTENANCE
3. Capture SOFTLOADSTATUSB logs as follows:
LOG SOFTLOADSTATUSB ONNEW
For information about the SOFTLOADSTATUSB log, see SOFTLOADSTATUSB on Page 124.
4. Start the software load process by executing the following command.
SOFTLOADRESET
5. Load the contents of the firmware update file (XXXX.hex) into a RAM buffer on the G-III
Reference Receiver. The contents of the firmware update file are loaded using a script or utility
created to load all of the individual S-Records contained in the hex file. For information about how
to create this script or utility, see Script Basics for Loading the Firmware Update File on Page
131.