Connect To The Maintenance Port; Configure The Ethernet Port Settings - Novatel WAAS G-III User Manual

Reference receiver
Table of Contents

Advertisement

Chapter 2
If the default Ethernet settings are compatible with your network, go to Section 2.1.5 Connect the Ethernet
ports on page 24.
If the default Ethernet setting are not compatible with your network, go to Section 2.2.2 Connect to the
Maintenance port on page 26.
2.2.2

Connect to the Maintenance port

To use the Maintenance port, the serial port settings of the computer you are using must match the following:
RS-232C protocol
115200 bits per second (bps)
No parity
8 data bits
1 stop bit
No handshaking
Echo off
You cannot change the port settings for the Maintenance port.
After you have configured the serial port settings on your computer, connect a serial cable with a DB9
connector from the computer to the Maintenance port (J05) on the G-III Reference Receiver. Refer to Table 54,
Port Specifications on Page 136.
From the Maintenance port, you can configure the settings for the Ethernet ports. See Section 2.2.3, Configure
the Ethernet Port Settings on Page 26.
2.2.3

Configure the Ethernet Port Settings

From the computer connected to the Maintenance port, enter the following commands to configure the Ethernet
ports.
1. If you are configuring the Data port, skip to the next step.
If you are configuring the Monitor port, use the ICOMCONFIG command to set the virtual COM
port, UDP port and peer IP addresses.
See Section 4.4.12, ICOMCONFIG on Page 57 for information about using the ICOMCONFIG
command.
26
Table 6: Monitor port default settings
Setting
IP Addressing Mode
IP Address
Netmask
Gateway
WAAS G-III Reference Receiver User Manual Rev 1
Value
Static
0.0.0.0
0.0.0.0
0.0.0.0
Installation