Toshiba TOSVERT VF-S11 Instruction Manual page 44

New global standard inverter
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

2.2.2
Standard connection diagram 2
Main circuit power supply
200V class: three-phase 200-240V
-50/60Hz
400V class: three-phase 380-500V
-50/60Hz
Protective function
MCCB(2P)
activation output
Power supply
R/L1
1 200 240V
-50/60Hz
S/L2
*1: The T/L3 terminal is not provided
for single-phase models.
Use the R/L1 and S/L2 terminal
as input terminals.
*2 The inverter came with the PO
and the PA/+ terminals shorted by
means of a shorting bar.
Before installing the DC reactor (DCL),
remove the bar.
*3: When using the NO output terminal in
source logic mode, short-circuit the P24 and
OUT terminals.
Standard connection diagram - source (common:P24)
DC reactor (DCL)
*2 (option)
P0
MCCB
R/L1
S/L2
Noise
filter
T/L3
*1
FLC
FLB
FLA
RY
Low-speed
signal output
RC
PLC
FM
+
Meter
Frequency
meter
(ammeter)
-
Braking resistor (option)
PA/+
PB
PC/-
Main circuit
P24
Control
circuit
F
R
VF-S11
RES
Operation panel
S1
Connector for
common serial
S2
communications
SW1
FM
VIA
S3
SOURCE
V
V
P24
OUT
NO
SINK
I
I
CC
CC VIA VIB
PP
External potentiometer (1~10k )
(or input voltage signal across VIB-CC terminals: 0-10V)
B-5
E6581158
Motor
U/T1
V/T2
I M
W/T3
Forward (rotation signal)
Reverse (rotation signal)
Reset
Preset-speed 1
Preset-speed 2
Preset-speed 3
*3
Ry
Speed reach signal
output
+
Voltage signal: 0-10V
-
(Current signal: 4-20mA)
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents