Toshiba TOSVERT VF-S11 Instruction Manual page 161

New global standard inverter
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

How to set parameters
a) Operating method: Terminal input
Set the operation control mode selection
b) Use the S2 and S3 terminals for switching. (Instead, other terminals may be used.)
S2: Acceleration/deceleration switching signal 1
S3: Acceleration/deceleration switching signal 2
Title
Function
Input terminal selection #5 (S2)
Input terminal selection #6 (S3)
Acceleration/ deceleration pattern
Acceleration/deceleration patterns can be selected individually, using the acceleration/deceleration 1, 2
and 3 parameters.
1) Linear acceleration/deceleration
2) S-pattern acceleration/deceleration 1
3) S-pattern acceleration/deceleration 2
Title
Function
Acceleration/ deceleration 1 pattern
Acceleration/ deceleration 2 pattern
Acceleration/ deceleration 3 pattern
For an explanation of acceleration/deceleration patterns, see 6.18.1.
Both the settings of the S-pattern lower-limit and upper-limit adjustment parameters (
) are applied to any acceleration/deceleration S-pattern.
to
.
Adjustment range
0-64
0-64
Adjustment range
: Linear,
: S-pattern 1,
pattern 2
: Linear,
: S-pattern 1,
pattern 2
: Linear,
: S-pattern 1,
pattern 2
F-59
E6581158
Setting value
5 (the second
acceleration/de
celeration
mode
selection)
58 (the third
acceleration/de
celeration
mode
selection)
Setting value
: S-
0
: S-
0
: S-
0
and
6

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents