Toshiba TOSVERT VF-S11 Instruction Manual page 105

New global standard inverter
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

6.1.2
Output of designated frequency reach signal
: Speed reach detection band
• Function
When the output frequency becomes equal to the setting by designated frequency ±
OFF signal is generated.
Parameter setting of designated frequency and detection band
Title
Speed reach detection band
Parameter setting of output terminal selection
Title
Function
Output terminal
selection 2A
(OUT-NO)
Note: Select the
FLA-FLC-FLB terminal output.
Designated frequency +
Designated frequency −
Set frequency speed reach signal
P24-OUT (Default setting)
RY-RC
FLA/FLC/DLB
Set frquency spped reach signal:
Inverted
Function
Adjustment range
0-255
(See Section 11, K-18)
parameter to specify RY-RC terminal output, or the
Output frequency [Hz]
Designated frequency
0
F-3
Adjustment range
0.0 ∼
(Hz)
Default setting
6: RCH (designated frequency - ON signal), or
7: RCHN (designated frequency - OFF signal)
E6581158
, an ON or
Default setting
2.5
parameter to specify
6
Time [s]
ON
OFF
ON
OFF

Hide quick links: