E6581922 - Contents - 1. Introduction ....................2 2. Trace function....................3 2.1 Related parameters ......................3 2.2 Acquisition of trace data......................5 2.2.1 Example of acquisition of trace data ................5 2.2.2 How to acquire the trace data ..................6 1...
RS485 communication and the software for trace function, PCT002Z-E, are used for VF-S15. Use PC to read data. *1: Please contact your Toshiba distributor for the software:PCT002Z-E. *2: USB converters unit (optional), USB cable (optional, A-B connection type), and commercially available USB cable are necessary to connect to the PC.
E6581922 2. Trace function VF-S15 retains the data collected at the time of tripping or triggering and reads out such data until resetting the tripped inverter or turning off the power. Up to 4 types of data can be selected from approximately 25, and 100 consecutive points can be stored as trace data.
Page 5
E6581922 [Setup values of f742 to f745] Commun Communicati Default ication Trace (monitor) function on unit at setting tracing 0 FD00 Output frequency (Hz/free unit) 0.01Hz 1 FD03 Output current (%/A) 0.01% Frequency command value (Hz/ free 2 FD02 0.01Hz unit) 3...
E6581922 2.2 Acquisition of trace data 2.2.1 Example of acquisition of trace data 1) To acquire trace data until the occurrence of tripping: f740=1, 3 (Examples of current date output) Trip Monitor value of output current Failure FL signa : Trace data Trace data 1 * In case of trigger input when setting f740=3, operation is that described in 3).
E6581922 2.2.2 How to acquire the trace data Use RS485 communication and the software for trace function, PCT002Z-E to acquire trace data. Trace data communication number Commun Minimum setting Setting/readout Default ication Function /readout unit range setting 0 to 99 0...