Toshiba TOSVERT VF-S11 Instruction Manual page 235

New global standard inverter
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

• Torque boost parameters
Communication
Title
Function
No.
0400
Auto-tuning
0401
Slip frequency
gain
0402
Motor constant #1
(primary
resistance)
0415
Motor rated
current
0416
Motor no-load
current
0417
Motor rated speed
0418
Speed control
response
coefficient
0419
Speed control
stability coefficient
0480
Exciting strength-
ening coefficient
0485
Stall cooperation
gain at field
weakening zone 1
0492
Stall cooperation
gain at field
weakening zone 2
0494
Motor adjustment
factor
*1 : Default values vary depending on the capacity. See the table of page K-14.
• Acceleration/deceleration time parameters
Communication
Title
Function
No.
0500
Acceleration time
2
0501
Deceleration time
2
0502
Acceleration/decel
eration 1 pattern
0503
Acceleration/decel
eration 2 pattern
0504
Acceleration/decel
eration selection
(1, 2 , 3)
0505
Acceleration/decel
eration 1 and 2
switching
frequency
0506
S-pattern lower-
limit adjustment
amount
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
-
-
0: Auto-tuning disabled
1: Initialization of
2: Auto-tuning enabled
(after execution: 0)
%
1/1
0-150
%
0.1/0.1
0.0-30.0
A
0.1/0.1
0.1-100.0
%
1/1
10-90
min-1
1/1
100-32000
-
1/1
1-150
-
1/1
1-100
%
1/1
100-130
-
1/1
10-250
-
1/1
50-150
-
1/1
0-200
Minimum
setting unit
Unit
Adjustment range
Panel/Commun
ication
s
0.1/0.1
0.0-3200
s
0.1/0.1
0.0-3200
-
-
0: Linear
1: S-pattern 1
2: S-pattern 2
-
-
-
-
1: Acceleration/deceleration 1
2: Acceleration/deceleration 2
3: Acceleration/deceleration 3
Hz
0.1/0. 1
0.0-
%
1/1
0-50
K-9
E6581158
Default
User
setting
setting
0
(reset to 0)
50
* 1
* 1
* 1
1410(WP)
1710
(WN, AN)
40
20
100
100
100
* 1
Default
User
setting
setting
10.0
10.0
0
0
1
0.0
10
Reference
6.17
Reference
11
6.18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents