6.4

Basic parameters 2

6.4.1
Switching motor characteristics via terminal input
: Base frequency 2
: Base frequency voltage 2
: Torque boost 2
: Motor electronic-thermal protection level 2
: Stall prevention level 2
• Function
Use the above parameters to switch the operation of two motors with a single inverter and to select
motor V/F characteristics (two types) according to the particular needs or operation mode.
Note: The
If motor 2 is selected, V/F control will be given constant torque characteristics.
Parameter setting
Title
Base frequency 2
Base frequency voltage 2
Torque boost 2
Motor electronic-thermal protection level 2
Stall prevention level 2
(V/F control mode selection) parameter is enabled only for motor1.
Function
F-15
Adjustment range
50.0 (WP type)
25.0-500.0 (Hz)
60.0 (WN, AN type)
200 (200V class) / 400
50-660 (V)
According to model
0.0-30.0 (%)
(See Section 11, K-14)
10-100 (%)
10-199 (%)
200 : Disabled
E6581158
6
Default setting
(400V class)
100
150

Hide quick links: