Figure 1-11. Removing the lamp from its socket.

5.
Put on your protective gloves. Remove the plastic shell containing the new lamp. Break the
seal, open the container and remove the lamp.
6.
Hold onto the ceramic lamp base and gently press the two lamp base pins into the brass lamp
sockets as shown in Figure 1-12. Do not force the lamp into the socket; doing so could break
the lamp.
Cautions
(1) Avoid touching any part of your skin to the lamp's quartz envelope.
Oil and residue from your fingers can create a "hot spot" on the lamp,
causing premature lamp aging.
(2) Do not adjust the three optimization screws labeled in Figure 1-12. You
will adjust these screws in a separate procedure, described in the section
titled "Optimizing the Cyberlight Fixture Lamp" on page 1-18.
Brass socket

Figure 1-12. Installing the new lamp into the socket.

7.
Before you insert the lamp assembly back into the fixture, clean the lamp with the alcohol wipe
shipped with the lamp. Otherwise, fingerprints and other contaminates will shorten lamp life.
8.
Carefully guide the lamp assembly straight back into the fixture and make sure the lamp is
inserted into the reflector. Be careful not to crimp the two lamp wires as you insert the lamp
assembly. Firmly tighten the two lamp assembly screws to secure the assembly to the fixture.
Brass socket
Optimization screws
(do not adjust)
Chapter 1 Installation and Setup 1-17