Replacing Parts; Replacing Power Supply Fuses - High End Systems Cyberlight User Manual

Automated luminaire
Table of Contents

Advertisement

Replacing Parts

This section explains how to remove and replace parts inside the fixture. Make note of the
following caution and warnings:
Caution
Equipment surfaces may reach temperatures up to 62° C (144° F). Allow
10 minutes for cooling before handling.
Warnings (1) An unshielded MSR/MSD 1200 lamp emits ultraviolet and visible
(UV-vis) radiation which could damage eyes and skin. Never look
directly at the lamp while lamp is on.
(2) Hot lamp may be an explosion hazard. Do not open for 5 minutes
after switching off. Wear eye and hand protection when re-lamping.
(3) Replace fuses only with the specified type and rating.
(4) Disconnect power before re-lamping or servicing.
After allowing the fixture to cool as described above, turn it OFF and unplug it from its power
source. Then see one of the following sections:
"Replacing Power Supply Fuses" on page 3-15
"Removing and Installing Rotating Lithos" on page 3-19
"Replacing Dichroics/Lithos in the Color Wheel or the Static Litho Wheel" on page 3-22
"Adjusting the Mechanical Zoom Lens (CX Only)" on page 3-23
"Adjusting the Mirror Head Deviation" on page 3-24
"Adjusting the Yoke Deviation" on page 3-26

Replacing Power Supply Fuses

This section explains how to replace the four fuses located on the Cyberlight power supply board.
You will need:
- 5/32 inch allen wrench
- Replacement fuses (5 mm by 20 mm only).
There are a total of four:
Amps
2.5 A
4 A
0.5 A
1.6 A
Volts
Fuse Type
250 V
Slow Blow Only
250 V
Fast Blow Only
250 V
Fast Blow Only
250 V
Fast Blow Only
Chapter 3 Servicing Your Cyberlight 3-15