Installing or Replacing the MSR 1200 Lamp

You will need:
Warnings (1) This equipment is designed for use with Philips
1.
2.
3.
4.
1-16 Cyberlight User Manual
– 1200 W, G-22 Base, MSR1200 or MSD1200 Metal Halide Lamp
Only
– Protective eye wear
– Protective gloves
MSD1200, 1200 watt lamp only. Use of any other type lamp may be
hazardous and will void the warranty.
(2) Change the lamp if it becomes damaged or thermally deformed.
(3) An unshielded MSR/MSD 1200 lamp emits ultraviolet and visible
(UV-vis) radiation which could damage eyes and skin. Whenever you are
working on or near an exposed MSR/MSD 1200 lamp, wear protective
eye gear. Never look directly at the lamp while lamp is on
(4) Hot lamp may be an explosion hazard. Do not open for 5 minutes
after switching off. Wear eye and hand protection when re-lamping.
Allow the fixture to cool as described above, then power OFF the fixture and unplug it from the
power source.
Fully back out the two lamp assembly screws shown in Figure 1-10. The screws have retaining
springs that prevent them from being removed.

Figure 1-10. Location of lamp assembly and optimization screws.

Grip the assembly by the three lamp optimizing screws and pull the assembly straight out the
back of the fixture. The lamp's power cord is long enough to allow you to pull the lamp
assembly entirely free of the Cyberlight.
When the lamp assembly is free, pull the old lamp straight up and out of the assembly as
shown in Figure 1-11:
®
type MSR1200 or
.