Figure 3-17. On Cl And Cx Models, Make Sure You Disconnect The Fan Power Wires From The Fan Connectors Before Removing The Lamp Box Access Door; Figure 3-18. Locations Of The Reflector And Infrared Filter - High End Systems Cyberlight User Manual

Automated luminaire
Table of Contents

Advertisement

Figure 3-17. On CL and CX models, make sure you disconnect the fan power wires
from the fan connectors before removing the lamp box access door.
8.
Using a lint-free cotton cloth and mild glass cleaner, wipe dust and dirt from the reflector and
infrared filter, which are shown in Figure 3-18. The infrared filter consists of two rose-colored
glass hemispheres directly in front of the reflector.

Figure 3-18. Locations of the reflector and infrared filter.

9.
Using a soft, lint-free cotton cloth, wipe excess dirt and dust from the other side of the infrared
filter and from the dim flags. There are two black, metallic dim flags on all Cyberlight models.
Their locations are described below:
If you have the CL or SV, the two dim flags are among the color mixing flags, so you
should clean all the flags at the same time. Manually "flip" each flag until it is in a
position where you can access it, then wipe the flag with a lint-free cloth. Dampen the
cloth with a mild glass cleaning solution if necessary to clean built-up dust and dirt. If a
color mixing flag is damaged or broken, or if you need to remove it in order to clean it,
contact Customer Service in one of the ways shown in the section titled "Getting Help" on
page Intro-4.