Switches 7 and 8: Protocol Mode
Use these switches to define the communication protocol between the fixture and the controller. By
default, switches 7 and 8 are both set OFF, which enables the use of Lightwave Research (LWR)
protocol for fixture control. This means you must use a controller that supports LWR protocol. The
Status Cue system and the Cyberlight LCD controller (both manufactured by High End Systems)
support LWR protocol. In addition, other vendors have controllers that support LWR; consult the
documentation provided with your controller for more information.
Table 2-2: Cyberlight Fixture Number Settings (LWR Protocol)
For This Fixture
Number
01
none
02
1
03
2
04
1 and 2
05
3
06
1 and 3
07
2 and 3
08
1, 2, and 3
09
4
10
1 and 4
11
2 and 4
12
1, 2, and 4
13
3 and 4
14
1, 3, and 4
15
2, 3, and 4
16
1, 2, 3, and 4
Table 2-1: Protocol Mode Switch Settings
Switches 7 and 8:
7
8
off off
LWR
off on
DMX 1
on off
DMX 2
on on
DMX 3
Set These DIP
For This Fixture
Switches ON
Mode
Set These DIP
Number
Switches ON
17
5
18
1 and 5
19
2 and 5
20
1, 2, and 5
21
3 and 5
22
1, 3, and 5
23
2, 3, and 5
24
1, 2, 3, and 5
25
4 and 5
26
1, 4, and 5
27
2, 4, and 5
28
1, 2, 4, and 5
29
3, 4, and 5
30
1, 3, 4, and 5
31
2, 3, 4, and 5
32
1, 2, 3, 4, and 5
Chapter 2 Using Your Cyberlight
2
2-5