8-24
Messages displayed on upper line
On-screen
Description
message
Prepare To Boot
POST completes normally.
CPU Reconfigured
POST completes with processor
degraded.
Mem Reconfigured
POST completes with memory degraded.
M#1 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #1.
M#1 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #1.
M#1 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #1.
M#1 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #1.
M#2 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #2.
A correctable error frequently occurs in
M#2 D#2 C Err
DIMM #2 on memory board #2.
M#2 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #2.
M#2 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #2.
M#3 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #3.
M#3 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #3.
M#3 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #3.
M#3 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #3.
M#4 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #4.
M#4 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #4.
M#4 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #4.
M#4 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #4.
Action
This is not an error.
Contact your service representative.
Try the following steps to cancel the error.
1. Start BIOS SETUP.
2. Select [Main] - Processor Settings] - [Processor Retest] -
[Yes].
3. Select [Exit] - [Exit Saving Changes].
Contact your service representative.
Try the following steps to cancel the error.
1. Start BIOS SETUP.
2. Select [Advanced] - [Memory Configuration] - [Memory
Retest] - [Yes].
3. Select [Exit] - [Exit Saving Changes].
The system can continue operation. However, consult with
your service representative.
The system can continue operation. However, consult with
your service representative.

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents