8-24
Messages displayed on upper line
On-screen
Description
message
Prepare To Boot
POST completes normally.
CPU Reconfigured
POST completes with processor
degraded.
Mem Reconfigured
POST completes with memory degraded.
M#1 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #1.
M#1 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #1.
M#1 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #1.
M#1 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #1.
M#2 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #2.
A correctable error frequently occurs in
M#2 D#2 C Err
DIMM #2 on memory board #2.
M#2 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #2.
M#2 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #2.
M#3 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #3.
M#3 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #3.
M#3 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #3.
M#3 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #3.
M#4 D#1 C Err
A correctable error frequently occurs in
DIMM #1 on memory board #4.
M#4 D#2 C Err
A correctable error frequently occurs in
DIMM #2 on memory board #4.
M#4 D#3 C Err
A correctable error frequently occurs in
DIMM #3 on memory board #4.
M#4 D#4 C Err
A correctable error frequently occurs in
DIMM #4 on memory board #4.
Action
This is not an error.
Contact your service representative.
Try the following steps to cancel the error.
1. Start BIOS SETUP.
2. Select [Main] - Processor Settings] - [Processor Retest] -
[Yes].
3. Select [Exit] - [Exit Saving Changes].
Contact your service representative.
Try the following steps to cancel the error.
1. Start BIOS SETUP.
2. Select [Advanced] - [Memory Configuration] - [Memory
Retest] - [Yes].
3. Select [Exit] - [Exit Saving Changes].
The system can continue operation. However, consult with
your service representative.
The system can continue operation. However, consult with
your service representative.