NOTES:
When configuration information on the disk array controller and the hard disk do not match
(excluding at replacement of faulty disk array controller), configuration cannot be performed
by selecting the configuration information on the disk array controller. In this case, perform
"Clear Configuration" to create configuration again.
MegaRAID Configuration Utility cannot delete each logical drive. Use Power Console Plus.
3.
Make Online.
Puts a hard disk in the FAIL status online.
Select "Objects" → "Physical Drive" → (select hard disk) → "Make Online" from the TOP menu.
4.
Battery
– Indicate battery information
Select "Objects" → "Adapter" → "Battery Information" from the top menu.
Backup Module
Battery Pack
Temperature
Voltage
Fast Charging
No of Cycle
– Clear battery charge counter
Select "Objects" → "Adapter" → "Reset Battery Charge Counter" from the top menu. Popup message appears.
Select "Yes" and press Enter.
NOTES:
Clear Battery Charge Counter when you exchange the battery.
The battery backup module must be replaced in two years or 500 times of charge and
discharge.
5.
Rebuild Rate
Sets rebuild rate.
Select "Objects" → "Adapter" → "Rebuild Rate" from the TOP menu.
Can be set in a range from 0% to 100%. The default value (recommended setting value) is "30%."
6.
Hard disk information
Checks hard disk information.
Select "Objects" → "Physical Drive" → (select disk) → "View Drive Information" from the TOP menu.
PRESENT
ABSENT
PRESENT
ABSENT
GOOD
HIGH
GOOD
LOW
COMPLETED
IN_PROGRESS
***
4-41