NEC Express5800 140Rd-4 User Manual page 102

Windows server 2003 x64 editions
Hide thumbs Also See for Express5800 140Rd-4:
Table of Contents

Advertisement

4-20
Server
Positioning the cursor on "Server" shows the Server menu.
The items which can be set on the Server menu and their functions are described below. For the setting, first select "System
Management" or "Console Redirection" and press Enter to display the proper submenu.
See the table below for the items.
Option
Parameter
Assert NMI
Disabled
on PERR
[Enabled]
Assert NMI
Disabled
on SERR
[Enabled]
FRB-2
Disable FRB2 Timer
Policy
[Disable BSP]
Do Not Disable BSP
Retry 3 Times
Boot
[Disabled]
Monitoring
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Boot
[Retry 3 Times]
Monitoring
Retry Service Boot
Policy
Always Retest
Thermal
Disabled
Sensor
[Enabled]
BMC IRQ
Disabled
[IRQ 11]
Post Error
Disabled
Pause
[Enabled]
Description
Indicates whether PCI PERR is supported or not.
If this item is set "Enabled", the system offers an error through the NMI
when an error occurred.
Indicates whether PCI SERR is supported or not.
If this item is set "Enabled", the system offers an error through the NMI
when an error occurred.
Set this item to "Disable BSP".
Indicates whether the boot monitoring function is enabled or disabled on
booting.
To use this function, install ESMPRO Agent. Do not use this function if the
system is booted from operating system without installation of ESMPRO
Agent or CD-ROM. Set this item to "Disabled" if ARCServe uses the
Disaster Recovery Option.
Appears when the boot monitoring feature is enabled. This item indicates
the processing at the occurrence of timeout during boot monitoring.
If [Retry 3 times] is selected, the system is reset after the occurrence of
timeout and operating system boot is retried up to three times. The failure
in the third boot causes the boot to be tried from the service partition.
If [Retry Service Boot] is selected, the system is reset after the occurrence
of timeout and operating system boot is retried up to three times. Then the
boot is tried from the service partition for three times.
If [Always Reset] is selected, the system is reset after the occurrence of
timeout and operating system boot is retried repeatedly.
Indicates whether the temperature sensor monitoring function is enabled
or disabled.
Indicates the IRQ of the BMC interrupt.
Indicates whether POST is aborted once at the end of POST if an error
occurs during the execution of POST.
Your Setting